How To Check Furnace Pilot Light: A Step-by-Step Homeowner Guide

How To Check Furnace Pilot Light: A Step-by-Step Homeowner Guide

Rheem Gas Furnace Pilot Light Instructions | Shelly Lighting

Checking a furnace pilot light requires locating the access panel, inspecting the color and stability of the small gas flame, and determining whether the assembly requires relighting or thermocouple servicing. Maintaining an optimal blue flame ensures heating efficiency and prevents unburned gas leaks in forced-air residential heating systems.


Pre-Operation & Safety Checklist

Inspecting a gas furnace pilot light involves working with natural gas or propane and open combustion zones. Proper preparation prevents carbon monoxide exposure, gas leaks, and accidental burns while ensuring the diagnostic process runs smoothly.



  • Essential Gear & Tools: Flashlight, long-reach utility lighter or matches, wire brush or emery cloth, and a digital multimeter for advanced testing.
  • Mandatory Prerequisite Knowledge: Familiarity with the emergency gas shutoff valve, the main gas valve control dial (typically featuring "On," "Off," and "Pilot" settings), and the physical layout of the burner assembly.
  • Budget & Duration Benchmarks: Financial cost is zero for visual inspections, ranging up to twenty dollars if a replacement thermocouple is required. Time investment ranges from five to fifteen minutes.

Step-by-Step Pilot Light Inspection Workflow



Step 1: Locate the Access Panel and Burner Compartment

Turn off the thermostat or set it to the lowest setting to prevent the main burners from firing unexpectedly during the inspection. Remove the lower front access panel or service door of the furnace by lifting it up and pulling it outward. Locate the gas control valve, which connects the external gas supply line to the internal burner manifold and houses the pilot assembly tubing.

Warning: If you smell a strong odor of gas immediately upon opening the panel, do not attempt to check or light the pilot. Evacuate the home immediately and call your local gas utility provider or emergency services from a safe distance.



Step 2: Visually Inspect the Pilot Flame Status

Shine your flashlight into the burner compartment to locate the pilot assembly, which sits adjacent to the main burner rack near the base of the combustion chamber. Observe the condition of the flame: a healthy pilot light burns as a sharp, steady blue cone enveloping the tip of the thermocouple. If the flame is absent, flickering yellow, or lazy and orange, the system is either unlit or experiencing combustion issues.

Pro-Tip: A yellow or orange flame indicates incomplete combustion, often caused by dust, soot, or port clogs, which can coat your heat exchanger over time and produce carbon monoxide.



Step 3: Evaluate Thermocouple Alignment and Voltage Output

Examine the small metal probe—known as the thermocouple—positioned directly in the path of the pilot flame. The flame should engulf the upper third to half of this probe to heat the bimetallic junction and generate the millivolt current required to keep the safety gas valve open. If the flame is touching the probe correctly but the gas valve refuses to stay open when released, the thermocouple has failed and requires electrical testing or replacement.



Step 4: Relight the Pilot Light Safely If Extinguished

If the pilot light is out, turn the main gas control knob from the "On" position to the "Off" position and wait at least five minutes to allow any residual gas to dissipate completely from the combustion chamber. Turn the control dial to the "Pilot" position, depress the reset button firmly, and apply your flame source to the pilot burner head while continuing to hold the button down for 30 to 60 seconds. Release the button slowly; if the flame remains stable, turn the dial back to the "On" position and replace the access panel.


How to Diagnose and Repair a Bad Furnace Ignitor | Vernon AC

How to Diagnose and Repair a Bad Furnace Ignitor | Vernon AC

Furnace Pilot System Comparison Parameters



Parameter Healthy Pilot Light Extinguished Pilot Failing Thermocouple Electronic Ignition (DSI/HSI)
Flame Characteristics Crisp blue cone, steady No flame present Weak, drifting flame No continuous pilot
Safety Device Thermocouple / Thermopile None active Millivolt safety switch Flame rectification sensor
Common Symptom Normal heating cycles Complete loss of heat Pilot goes out repeatedly Error codes on control board
Resolution Method None required Relight per manual Clean or replace probe Service igniter / clean sensor

Common System Failures & Field Fixes



  • Root Cause: Drafts or strong air currents within the utility room repeatedly blow out the pilot flame during operation.

    • Actionable Fix: Ensure the furnace closet or utility room has adequate combustion air supply, check that the access panel is securely sealed, and inspect for unsealed vent pipe penetrations.
  • Root Cause: Carbon buildup, soot, or mineral deposits blocking the tiny orifice of the pilot burner tube.

    • Actionable Fix: Turn off the gas supply, disconnect the pilot tubing carefully, and clean the pilot orifice using a specialized wire brush or compressed air before reassembling.
  • Root Cause: A loose or corroded electrical connection at the safety control valve terminal where the thermocouple screws in.

    • Actionable Fix: Unscrew the rear brass connection nut of the thermocouple at the gas valve, clean the contact point with fine-grit sandpaper, and hand-tighten plus a quarter-turn with a wrench. Do not over-tighten, as this strips the threads.

Frequently Asked Questions



Why does my furnace pilot light keep going out?

A pilot light typically goes out due to a dirty or failing thermocouple, a drafty utility room, a partially clogged pilot orifice, or a faulty safety control valve. If cleaning the thermocouple and relighting does not resolve the issue, the thermocouple likely needs replacement.



Is it safe to leave a yellow pilot light burning?

No, a yellow or orange flame indicates improper combustion and incomplete gas burn, which generates excessive soot and elevated levels of carbon monoxide. You should turn off the furnace and clean the burner assembly or call a professional technician.



How long should I hold the pilot button down when relighting?

You must hold the pilot reset button down for 30 to 60 seconds after the flame ignites. This gives the thermocouple enough time to heat up and generate sufficient millivolt power to hold the internal magnetic safety valve open.



Can modern furnaces have pilot lights?

Most high-efficiency furnaces manufactured after the early 1990s use electronic ignition systems, such as intermittent pilot ignition or hot surface igniters, rather than a standing continuous pilot light. Standing pilots are primarily found on older mid-efficiency and gravity-vented gas furnaces.



When should I call a professional HVAC technician?

You should call a certified technician if you smell persistent gas after turning off the supply, if the main burners fail to ignite after the pilot is lit, or if you suspect a cracked heat exchanger. Gas appliance repairs require specialized diagnostic tools like combustion analyzers and manometers.

Schedule your annual furnace maintenance checkup today to ensure your heating system operates safely, efficiently, and reliably all winter long.