How To Test A Pressure Switch On A Furnace: A Comprehensive Diagnostic Guide

How To Test A Pressure Switch On A Furnace: A Comprehensive Diagnostic Guide

Types & Problems of Pressure Switch | Pressure Switch Parts and Accessories

Testing a furnace pressure switch requires a digital multimeter capable of reading inches of water column (in. W.C.) or DC voltage, along with a handheld manometer. By isolating the switch, verifying closed-loop continuity, and checking draft pressure differential against the manufacturer specification stamped on the label, you can accurately determine if the component has failed or if an underlying venting issue is triggering a safety lockout.


--- Advertisement / Sponsored Links ---
Verified by SecureScan: No Viruses Detected
Format: Adobe PDF Downloads: 12,409 Size: 2.4 MB

Pre-Operation & Equipment Checklist

Proper diagnosis of a heating appliance safety device begins with thorough preparation, adherence to safety standards, and the assembly of precision testing instruments. The draft pressure switch is a vital safety interlock designed to prove that the induced draft blower is successfully expelling combustion gases before the gas valve energizes.



  • Essential gear, tools, and materials: Digital multimeter (capable of measuring millivolts, AC/DC volts, and ohms), a digital manometer with silicone tubing, a small flathead screwdriver, alligator clip test leads, and standard wire strippers or back-probing pins.
  • Mandatory prerequisite knowledge and safety standards: Technicians must understand basic low-voltage circuits (24VAC control systems), follow National Fuel Gas Code (NFPA 54) guidelines regarding venting integrity, and always kill both 120VAC power to the furnace and 24VAC control power before disconnecting any internal wiring.
  • Estimated budget and duration benchmarks: Tools range from 50 to 200 dollars depending on manometer quality; the diagnostic procedure itself typically takes 15 to 30 minutes for an experienced technician.

Step-by-Step Diagnostic Workflow



Step 1: Secure the Work Area and Kill Power

Begin by shutting off the 120-volt power switch mounted on or near the furnace housing, and turn off the thermostat call for heat to drop the 24VAC transformer load. Remove the upper burner compartment door panel to expose the induced draft blower assembly and the round or rectangular mechanical pressure switch, which is typically mounted on the internal vestibule panel.

Warning: Never bypass a furnace pressure switch with a permanent jumper wire during normal operation, as this defeats a critical carbon monoxide safety interlock. Temporary jumpers should only be used for brief diagnostic verification while you are actively monitoring the equipment.



Step 2: Inspect Tubing and Port Integrity

Locate the silicone or rubber tubing running from the pressure switch barb to a port on the draft inducer housing or the collector box. Pull the tubing away from the switch and inspect it thoroughly for cracks, dry rot, pinhole leaks, or internal condensation and soot blockages. Clear any debris from the draft inducer pressure tap using a small drill bit or paperclip (ensuring the furnace remains powered off), and reattach secure tubing connections before moving forward.



Step 3: Measure Static and Operating Pressure Differential

Connect your digital manometer to the pressure switch tubing using a tee fitting, or disconnect the tube from the switch entirely and connect it directly to the high port of the manometer. Turn the furnace power back on, restore the call for heat, and observe the manometer reading the exact moment the inducer motor spins up. Compare this real-time draft pressure measurement in inches of water column against the closing setpoint printed on the face of the pressure switch label (for example, negative 0.65 in. W.C.).

Pro-Tip: If your manometer reads a negative pressure that exceeds the switch rating (meaning the draft is strong enough), yet the switch still fails to close electrically, the internal diaphragm has likely ruptured or stiffened.



Step 4: Perform Electrical Continuity and Voltage Tests

Set your digital multimeter to the DC voltage scale to measure across the low-voltage terminals of the pressure switch while the inducer motor is actively running. Place your meter probes on the two switch terminals; if the switch is properly closed and making internal contact, your meter should read 0 volts (since there is no voltage drop across a closed switch). If your meter reads 24 volts across the switch terminals while the inducer is running, it indicates an open circuit, meaning the switch contacts have failed to close despite adequate draft pressure.


Pressure Switch Tester at Andy Sage blog

Pressure Switch Tester at Andy Sage blog

Furnace Pressure Switch Specifications and Diagnostic Parameters



Parameter Normal Operating State Common Failure Indicator Diagnostic Action Required
Draft Pressure Meets or exceeds manufacturer in. W.C. rating Below setpoint value Inspect venting, clean inducer port, clear secondary heat exchanger
Tubing Condition Clear, pliable, airtight fit on barbs Cracked, pinched, or filled with water condensation Replace silicone tubing or drain trapped moisture
Switch Continuity 0 ohms (Closed) during inducer run cycle Infinite ohms (Open) under running conditions Verify 24VAC drop or replace faulty pressure switch assembly
Diaphragm Action Crisp mechanical click upon pressure application Stuck open/closed, sluggish movement, or internal air leak Replace pressure switch; never attempt field calibration

Common Site Failures and Field Fixes



  • Root Cause: Blocked or restricted flue exhaust pipe due to leaves, bird nests, or heavy ice accumulation in cold climates.

    • Actionable Fix: Clear the exterior termination cap and use a camera snake to inspect the vertical and horizontal PVC venting runs for structural sagging or pooled condensate.
  • Root Cause: Condensation trapped inside the pressure switch sensing tube or internal diaphragm chamber.

    • Actionable Fix: Disconnect the tubing, drain any water droplets, blow air through the line to dry it completely, and check if the switch mounts at an angle that promotes pooling.
  • Root Cause: Secondary heat exchanger blockage causing excessive backpressure and failing draft.

    • Actionable Fix: Inspect the secondary heat exchanger cells for calcium scaling or soot buildup using a boroscope, and clean or replace the assembly according to manufacturer service bulletins.
  • Root Cause: Electrical chatter or high contact resistance caused by micro-corrosion on the push-on spade terminals.

    • Actionable Fix: Pull the wire terminals off the switch, clean the male spades with electrical contact cleaner and a fine wire brush, and crimp the female connectors slightly for a tighter mechanical grip.

Frequently Asked Questions



What causes a furnace pressure switch to keep clicking or opening rapidly?

Rapid clicking usually indicates a marginal draft pressure state where the inducer pulls just enough vacuum to close the switch momentarily, but minor pressure fluctuations cause it to drop out again. This is frequently caused by a partially blocked flue, a failing inducer motor capacitor, or high winds blowing down into the exhaust termination.



Can I adjust or repair a faulty furnace pressure switch?

No, pressure switches are factory-calibrated safety devices sealed with tamper-resistant lacquer. Adjusting internal setpoint screws or attempting to fix a torn internal silicone diaphragm compromises combustion safety and requires immediate component replacement with an exact OEM-matched part.



Will a bad pressure switch prevent the furnace igniter from glowing?

Yes, the pressure switch is part of the primary safety control chain sequence. If the integrated furnace control board does not receive a closed signal from the pressure switch after the inducer motor starts, it halts the ignition sequence and prevents both the hot surface igniter from glowing and the gas valve from opening.



How do I know if the problem is the switch or the inducer motor?

Attach a manometer to check the actual draft pressure and a multimeter to check voltage. If the manometer shows the system is generating the exact negative pressure required by the switch label, but the switch electrical contacts remain open, the switch is bad. If the manometer shows zero or very low pressure, the inducer motor, venting, or pressure tap is at fault.

Ready to restore your heating system's reliability with professional-grade replacement components and expert diagnostic support? Contact our certified HVAC parts specialists today to find the exact OEM pressure switch for your furnace make and model.


How To Test Pressure Switch With Multimeter | Gas Furnace

How To Test Pressure Switch With Multimeter | Gas Furnace